Close detail of tensioned woven wire mesh under inspection
NPL-traceable laboratory

Certified against the national standard.

A sieve is a measuring instrument, and a measuring instrument is only as good as its calibration. We inspect and certify in our own laboratory, against reference standards traceable to CSIR-NPL, the national metrology institute of India.

What we measure

Aperture and wire, opening by opening.

Following ISO 3310-1, we measure the mesh aperture and the wire diameter and check them against the tolerances the standard allows. How many openings we measure, and how much we report, is what separates the three grades.

NPL

Traceable to CSIR-NPLNational Physical Laboratory, India

We certify the sieves we build, and we re-certify yours. A working sieve wears; periodic recalibration keeps it honest.

Grade 01

Compliance

Openings verified by a statistical sample against ISO 3310-1 and ASTM E11 tolerances. Issued with a certificate confirming the sieve meets the standard.

Best forRoutine QC and everyday production sieving.
Grade 02

Inspection

A larger sample of openings measured and reported, with the mean aperture and spread stated. More apertures, more confidence in the number.

Best forMethod validation and audited laboratories.
Grade 03

Calibration

The most openings measured and individually reported, for sieves that serve as reference masters or settle a dispute. The highest rigor we offer.

Best forReference master sieves and referee testing.

All three grades are measured against the same NPL-traceable references. What rises across the grades is the number of apertures verified and the detail reported, not the honesty of the mesh underneath.

The traceability chain

From your bench back to the standard.

01

Your sieve

The working sieve on your bench, new from us or sent in for re-certification.

02

Our references

Measured against reference standards and instruments held in our laboratory and kept under calibration.

03

CSIR-NPL

Those references trace to the national metrology institute of India, closing the chain to the national standard.

On the certificate

A document you can hand an auditor.

Every certificate ties to the individual serial number engraved on the frame, so the paper and the sieve can never drift apart. Measured values, tolerances and the result sit on one page, with the traceability statement.

Re-certification is the other half of the story. Wire wears, frames take knocks, and apertures open up with use. A scheduled recalibration keeps a working sieve inside tolerance long after its first day.

VersatileCertificate of Calibration
Sieve serial201812001
Nominal aperture212 µm · ASTM No. 70
StandardISO 3310-1 : 2016
GradeCalibration
Mean aperture210.4 µm
ResultWithin tolerance

Traceable to CSIR-NPL, IndiaIllustrative layout

Worldwide enquiry

Send us your sieves. We will certify them.

New sieves ship with the grade you choose. Existing sieves, ours or another maker’s, come into the laboratory for inspection and re-certification. Ask us for a schedule.

Versatile Equipments Pvt Ltd · Kolhapur, India
Precision · foundry sand testing since 1966